YOUR LOCATION:HOME > Laboratory renovationLaboratory renovation

实验室装修

Laboratory engineering are divided into: indoor special construction sub-project decoration, water and electricity installationVENTILATING & AIR installation.

 

1.Interior decoration design

 

Modern laboratory renovation design with light, fresh color tone, simple, natural, stylish, atmospheric blend, not only embodies the modern laboratory of functional requirements, but also great to meet ergonomic standards.

Lab GroundFor the different requirements of different types of laboratory, ground requires a different handling

Ceiling Lab:Different laboratories may use different ceiling Ceiling ways, such as: light steel keel ceiling, gypsum board ceiling, lighting embedded Grille, according to the user's specifications and Ceiling design requirements

Lab wallAccording to the laboratory using different wall partition processing different materials, such as: color steel partition, glass partition and so on.

Lab Noise: In accordance with the relevant national standards, the laboratory shall not exceed 55dB noise

 

Also on the special requirements such as number of laboratory biosafety laboratory renovation we need to follow the relevant technical specifications

 

2.Hydropower installation

Water supply and drainage system

Water supply systemLab experiments of water supply system includes a water supply system, domestic water supply system. Different laboratories have different requirements for the test water, water is generally Lab: ordinary tap water, distilled water (triple-distilled water), ultra-pure water (deionized water).

Drainage systemLaboratory contamination of water generally corrosive water, organic corrosion in water, inorganic water pollution, as well as heavy metal pollution in water. Method Lab handling different polluted water drainage system according to the different needs of Lab, the total should be consistent with GB 8703-88 "Regulations for radiation protection."

 

Supply and distribution systemPower applications in accordance with the strength of power transmission power can be divided into strong and weak electrical categories.

Strong power systemFerroelectric generally refers to the exchange 220V50Hz and over current. Features - high voltage, current, power, low frequency.The main problem - reduce losses and improve efficiency, safetyStrong electrical system includes power distribution systems, power systems, lighting systems, lightning protection and grounding system

 

Weak systemsGenerally refers to a DC voltage is typically less than 24V. Features - Low voltage, current, power of smallWeak system includes monitoring systems, communications engineering (telephone), intelligent fire engineering, integrated wiring works.


Intellectualization SystemsTo construction equipment monitoring systems, security systems, communication networks, information network system, automatic fire alarm and fire linkage ferroelectric intrusion detectors and other systems, centralized monitoring, control and management for the purpose of constituting the integrated system

 

Selection of electrical productsLaboratory of selected electrical accessory products are industry-leading brand

 

3.HVAC installation:

Experimental Architecture are different from ordinary buildings, different laboratories on the temperature, humidity, pressure and cleanliness parameters have different requirements, and different Lab air can not cross-contamination. Experimental Architecture requires air conditioning systems more complex than that of a typical building of more

Air-conditioning system according to arrangement, divided into decentralized air conditioning system, centralized air-conditioning system and a local centralized air-conditioning system

Ordinary physical and chemical laboratoryUnit type air conditioner system (home wall machine, Guiji air conditioning); VRV air conditioning system, fan coil air conditioning system

Constant temperature and humidity Lab:Constant temperature and humidity precision air conditioning system (Once、 Quadratic return air system)

Clean laboratoryDI pipeline unit+Pressurized air box + high efficiency filter

④Ordinary office:Unit type air conditioner system (home wall machine, Guiji air conditioning); VRV air conditioning system, fan coil air conditioning system

 

4.Fresh air supply system:Temperature, humidity, cleanliness and precision control of the laboratory, which must be guaranteed by the tightness of the long-term reliable operation of precision air-conditioning systems and room. Fresh air must be plenty of fresh clean air, fresh air and not directly into the lab, through the air filter should be treated and then sent to Lab. At the same time add some fresh air, you can maintain Lab moderate pressure to prevent dust from entering. Specific configuration according to Lab needs to decide.

Air exhaust systemLaboratory experiments Air exhaust mainly need to solve the safety of personnel and laboratory environments. Lab exhaust air specific configuration depends on the specific nature of the laboratory, to arrange the size of positive and negative pressure. Determine the number of air flow and ventilation.